Lochinvar® Knight™ WHN056 Fire Tube Boiler, 95 % AFUE, 8.2 to 55 MBtu/hr BTU, 2.3 gal Capacity, 120 V
by Lochinvar®
Sold out
Original price
$5,731.00
-
Original price
$5,731.00
Original price
$5,731.00
$5,731.00
-
$5,731.00
Current price
$5,731.00
Lochinvar® Knight™ Fire Tube Boiler, 120 V, 95 % AFUE, 8.2 to 55 MBtu/hr BTU, 2.3 gal Capacity, Automatic Vent, Chimney/Breeching/Vent Size: 2 in, 15 A Fuse, Direct Spark Ignition, Net Rating: 44 MBtu/hr, Wall Mounting, Additional Information: 51 MBtu/hr Heating Capacity
- Stainless steel heat exchanger allows system water to flow around specially designed tubes for maximum heat transfer, while providing protection against flue gas corrosion
- Combustion chamber access cover allows access to the combustion side of the heat exchanger
- The blower pulls in air and gas through the venture
- Air and gas mix inside the blower and are pushed into the burner, where they burn inside the combustion chamber
- The gas valve senses the negative pressure created by the blower, allowing gas to flow only if the gas valve is powered and combustion air is flowing
- The venture controls air and gas flow into the burner
- This sensor monitors the flue gas exit temperature
- The control module will modulate and shut down the boiler if flue gas temperature gets too hot
- This protects the flue pipe from overheating
- Boiler outlet temperature sensor (housed with the high limit sensor) monitors boiler outlet water temperature (system supply)
- If selected as the controlling sensor, the control module adjusts the boiler firing rate so the outlet temperature is correct
- Boiler inlet temperature sensor monitors return water temperature (system return)
- If selected as the controlling sensor, the control module adjusts the boiler firing rate so the inlet temperature is correct
- Temperature and pressure gauge (field installed, not shown) monitors the outlet temperature of the boiler as well as the system water pressure
- Electronic LCD display features a high resolution liquid crystal screen, three buttons and a navigation dial
- A serial and USB port support additional communication with the control
- Flue pipe adapter llows for the connection of the vent system to the boiler
- Burner made with metal fiber and stainless steel construction, the burner uses pre-mixed air and gas and provides a wide range of firing rates
- Gas threaded pipe connection
- This pipe should be connected to the incoming gas supply for the purpose of delivering gas to the boiler
Specifications
| Voltage Rating | 120 V |
| Vent Type | Automatic |
| Mounting Type | Wall |
| AFUE Rating | 95 % |
| Net Rating | 44 MBtu/hr |
| BTU Rating | 8.2 to 55 MBtu/hr |
| Ignition Type | Direct Spark |
| Additional Information | 51 MBtu/hr Heating Capacity |
| Chimney/Breeching/Vent Size | 2 in |
| Fuse Rating | 15 A |
| Capacity | 2.3 gal |